Sargent and Greenleaf 6120 Spezifikationen Seite 6

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 11
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 5
page 6
b. Creating User Codes
Using the Master or Supervisor Code, create new User Codes. For each user, create a unique 6-digit code
and assign a PIN position (2 through 8). PIN position 9 is also available as a normal User Code if the Time
Delay Override feature is turned off. Note that PIN positions 4 through 8 are not available if the lock’s
duress function is enabled. For example, to create a new user in PIN position 3, you would enter:
7 4 * Master or Supervisor Code #

3 #

New User Code #

New User Code #

Security Note: After setting up a new User Code, it is recommended that each User change his/her code to
a unique 6-digit code of their choice.
c. Changing Codes
The Master, Supervisor, Users and TDO code holders can change their own 6-digit codes using command
2 2 * (or alphabetic characters C C, for “Change Code”). Enter:
2 2 * Old User Code #

New User Code #

New User Code #

d. Deleting Codes
To delete the Supervisor or a specific User (the Master Code may be changed but not deleted), you only
need to know the PIN position. The example below shows the deletion of the User in PIN 3.
7 4 * Master or Supervisor Code #

3 #

#

#

e. Detecting Active User Positions
You can identify active PIN positions for which codes are present (PIN 0-9). Each number on the keypad
corresponds to a PIN position. Enter:
7 7 * [ 0, 1, 2, 3, 4, 5, 6, 7, 8, 9 ] PIN position
If the lock beeps one high short beep when pressing a number key on the keypad, that PIN position is
active. If it beeps one low long beep, it is not active.
IV. Time Delay
Time Delay is a security feature that creates a period of time between the entering of a valid code and the
ability to open the safe door. Time delay can be set to delay opening from 1 to 99 minutes. Security Note:
If time delay has already been set, changes to the opening window and time delay durations can only be
made during the opening window period.
Seitenansicht 5
1 2 3 4 5 6 7 8 9 10 11

Kommentare zu diesen Handbüchern

Keine Kommentare