page 10
VI. Duress Function
(Order duress mOdule separately)
Your lock has duress capability (a silent alarm option). Installation of a duress signal box (duress module)
is required for proper connection to your existing alarm system. Use the instructions provided with the
module to ensure accurate installation and connection.
a. Enabling the Duress Feature
When the lock is installed with the duress module, you need to enable duress feature. Note that doing so
automatically deletes and disables User Codes 4 through 8. PIN positions 4 through 8 are not usable when duress is turned on.
To turn on the duress feature, press:
3 8 * Master Code #

1 #

1 #

When the duress feature is enabled, you can send a duress signal (silent alarm) by altering the last number
of your lock code by plus 1. For example, if your code is 246812, you would enter 24681
3 to send the
duress signal to your alarm company. When you use a duress code, the lock operates normally.
a. Disabling the Duress Feature
Disabling the duress feature automatically restores the functionality of PIN positions 4 through 8. You will be able to
program User Codes into these positions. To turn off the duress feature, press:
3 8 * Master Code #

0 #

0 #

VII. Audit Trail Options
a. Event Audit Trail
(O
rder audit trail keypad extensiOn separately)
This function keeps a sequential record of lock opening and programming events. This Event Audit Trail is
stored in the lock memory and can be downloaded to a computer (this requires the installation of a keypad
extension).
2 8 * Master Code #
The lock beeps 3 times () when the download is complete.
VIII. Codes—General Information
After changing the opening code, the lock should be opened and locked several times with the safe door
open.
Important: do not select codes such as birthdays or other predictable data which could provide a
correlation between the user and the opening code.